Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company
Registered Capital:
500000 RMB
Plant Area:
<100 square meters
Management System Certification:
ISO 9001, GMP, BRC
Average Lead Time:
Peak season lead time: within 15 workdays
Off season lead time: within 15 workdays
OEM/ODM Service
Sample Available

Hemodialysis Machine China, Haemodialysis Analyzer Machine, Dialysis Fluid manufacturer / supplier in China, offering Intelligent Operation System Hemodialysis Machine, TUV Ce FDA Certificate Non- Contact Digital Infrared Thermometer Temperature Gun, Smart Hand Wash Santinizer Automatic Soap Dispenser and so on.

Diamond Member Since 2013
Audited Supplier

Intelligent Operation System Hemodialysis Machine

Min. Order / Reference FOB Price
1 Piece US $7,500/ Piece
Production Capacity: 300 Per Month
Transport Package: Standar Export Packing
Payment Terms: L/C, T/T, Paypal, Western Union
Classification: Biochemical Apparatus
Type: Urine/Hematology Analyzer
Certification: CE, FDA, EEC, ISO13485
Dispayer: 5.7inch 240X160,Stn LCD Screen
Storage: 1000 Sample Results
Speed: 45 Tests/Hour

You Might Also Like

Loading...

Basic Info.

Model NO.
MSLHM01
Printout
Built-in Thermal Printer
Power
220V+/-10% 50/60Hz
Dimensions
Approx.340mm(D)X400mm(W)X360mm(H)
Weight
15kg
Features
Touch Screen
Sample Volume
20UL
Measurement Principle
Electrical Resistance Method
Trademark
MSL
Specification
340mm(D)X400mm(W)X360mm(H)
Origin
Guangdong
HS Code
9027809900

Main Features of MSL Semi-automatic Hematology Analyzer
Opening reagents. (You could use most of the reagents in your city).
Used on Human or Vet. (We have humany type and vet type in this model,the vet type could set different species of animal)
Touch screen.
Competive price in the market. ( One of the most pupolar model accepted by customers).
Fastest delivery. 

Measurement Parameters
RBC,MCV,HCT,RDW-CV, HGB,MCH,MCHC,PLT, MPV, PDW, PCT,
WBC,LYM#,LYM%,MID#,MID%,DRA#,GRA%,P-LCR,RDW-SD,
S-T(SAMPLE TEMPERATURE),
WBC,RBC,PLT HISTOGRAM
Measurement Principleelectrical resistance method
Sample volume20Ul
Speed45 tests/hour
Measurement channelsingle channel 80Ul
Storage1000 sample results
Dispayer5.7inch 240X160,STN LCD screen
Printoutbuilt-in thermal printer
interfaceRS-232(available for external printer)
Power220V+/-10% 50/60Hz
Dimensionsapprox.340mm(D)X400mm(W)X360mm(H)
Weight15Kg
PS: DIALYSIS MACHINE APPROVED BY CE
PACKING: STANDARD EXPORT PACKAGE
FOAM PAPER INNER AND PLYWOOD BOX OUTSIDE
 
 
Intelligent operation system; Easy operation with visual and audio alarms; Multi-purpose service/maintenance interface; Profiling: sodium concentration and UF curve;
 
Main performance of this device:
 
1Self-checking function
2Carbonate dialysis
3 Double needle dialysis
4 Liquid level detector
5Bubble detector
6Blood leakage detector
7Temperature and electric conductivity monitoring
8Arterial pressure, venous pressure and transmembrane pressure monitoring;
 9. Rolling blood pump;
10. Heparin pump;
11. Dehydration amount controlled by capacity;
12. Automatic disinfection cleaning program;
13. Stand-by power of blood pump in case of power failure;
14. Information display function of display screen.
 
*This device is designed and manufactured in strict accordance with the
Requirements of national laws and regulations. The reference standards of design and manufacture are following: GB9706.1-2007; GB9706.2-2003; and YY0054-2003.
 
Technical Parameter
Size &Weight:
Size: 380mmx400x1380mm (L*W*H);
Area: 500*520mm;
Weight: 88KG;
 
Power supply:
AC220V, 50Hz/60Hz, 10A
Input power: 1500W
Back-up battery: 30 minutes
 
Working Condition:
Water input pressure: 0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature: 5ºC~30ºC
Working environment temperature: 10ºC~30ºC at relative humidity <=70%
 
 
UF rate:
Flow range: 0ml/h~4000ml/h
Resolution ratio: 1ml
Precision: ±30ml/h
 
Blood pump &Spare pump:
Blood pump flow range: 30ml/min~600ml/min (diameter: 8mm or 6mm)
Spare pump flow range: 30ml/min~600ml/min (diameter 8mm or 6mm)
Resolution ratio: 0.1ml
Precision: ±10ml or 10% of reading
 
Heparin pump:
Syringe size: 20, 30, 50ml
Flow range: 0ml/h~10ml/h
Resolution ratio: 0.1ml
Precision: ±5%
 
Monitoring system &Alarm setup:
Venous pressure: -180mmHg ~ +600mmHg, ±10mmHg
Arterial pressure: -380mmHg ~ +400mmHg, ±10mmHg
TMP   pressure: -180mmHg ~ +600mmHg, ±20mmHg
Dialysate temperature: preset range 34.0ºC~39.0ºC
Blood leak detection: Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate.
Bubble detection: Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow
Conductivity: Acoustic-optic
 
Disinfection/Sanitize:
1. Heat disinfection:
Time: 30 minutes; Temperature: about 80ºC, at flow rate 500ml/min;
2. Chemical disinfection:
Time: 30minutes, Temperature: about 36ºC~50ºC, at flow rate 500ml/min;
3. Chemical disinfection with heat:
Time: 45minutes, Temperature: about 36ºC~80ºC, at flow rate 50ml/min;
4. Rinse:
Time: 10minutes, Temperature: about 37ºC, at flow rate 800ml/min;
 
Storage Environment:
Storage temperature should be between 5ºC~40ºC, at relative humidity <=80%

Send your message to this supplier